Exodus T-2800

Technical Advantages:

Three key functions are integrated: sample pre-processing, Isolation, and automatic recovery.

Protein removal efficiency >99%, with particle-to-protein ratio >3×108 particles/ug protein; exosome concentration >1×1011 particles/mL.

Bacteria-free, low endotoxin, minimize protein residuals from samples.

Fully automatic workflow that ensures batch-to-batch stability, whole-process status monitoring, and intelligent handling.

A single-use approach: fully enclosed consumables that meet pharmacopeial standards, i.e., sterile and endotoxin-free products. The system and software comply with GMP and 21 CFR part 11 requirements, respectively.

Lifecycle regulatory certification

  • Certification of clean production facilities in accordance with GMP requirements
  • Certification of physical performance according to regulatory requirements
  • Certification of chemical performance according to regulatory requirements
  • Certification of biological performance according to regulatory requirements
  • Certification of sterility and seal integrity
  • Certification of electrical safety standards
  • Certification of electromagnetic compatibility standards
  • Certification of packaging and transportation standards
  • 3Q certification in accordance with GMP requirements
  • Certification of environmental protection standards

certifications

Conducting lifecycle regulatory certification in East Asia, North America, the European Union, the Middle East, and other regions:


Specifications

Processing Volume0.5-10 L
Concentration Ratio≥100 times concentration, adjustable concentration ratio
Exosome Recovery VolumeAdjustable according to the concentration ratio
Exosome Resuspension SystemExosomes can be resuspended in PBS buffer or saline solution, tailored to meet the requirements of downstream application
Protein Removal Efficiency>99%
Particle-to-protein Ratio>1×108 particles/μg protein
Exosome Particle Concentration>1×1011-12 particles/mL, varies based on the sample type and isolation program
Temperature ControlSample position, buffer position, and exosome recovery station, with a controlled temperature range of 2-8°C
Display ScreenFeatures a 10.4-inch TFT touch screen that provides real-time updates on sample type, timing, purification progress, and more, facilitating standalone operation without the need of an additional computer
System Interface1 power port, 4 USB ports, and 1 network port
Dimensions820 mm × 500 mm × 685 mm
Net Weight≤200 lbs (90 kg)
Operating EnvironmentVoltage: AC 110 V-240 V, 50/60 Hz
Operating Temperature: 10-30°C
Operating Humidity: 30-85%, non-condensing